Fluoroscopy is a dynamic imaging tool that offers real-time visualization of internal anatomy and physiological processes. It’s indispensable in a wide range of diagnostic and interventional procedures, from barium studies to complex vascular interventions. But with this powerful modality comes an increased responsibility: managing radiation exposure to patients and staff.
Because fluoroscopy often involves longer exposure times than standard radiographic imaging, technologists and radiologists must ap...

In radiographic imaging, the balance between diagnostic clarity and patient safety is achieved not just through technology, but through technique—especially positioning. How a patient is aligned relative to the x-ray beam, image receptor, and anatomical area of interest profoundly influences the amount of radiation required, the need for repeat exams, and the accuracy of diagnosis.
Positioning is often overlooked as a radiation safety tool, but in reality, it is one of the most effective ways to minimi...

In the world of diagnostic radiology, image quality and patient safety must coexist in every decision made by the technologist. While collimation, filtration, and receptor selection all play critical roles in radiation protection, one often misunderstood tool in the imaging chain is the grid. Primarily used to improve image contrast by reducing scatter radiation, grids can also influence patient dose in ways that require careful management and expertise.
In this post, we will explore:
-
What grids a
...

In the realm of diagnostic imaging, technological advances have continuously reshaped the way radiologic professionals balance diagnostic quality with patient safety. One of the most critical elements in this equation is the image receptor—the device or medium that captures the diagnostic image produced by x-rays passing through the body. The type and performance of image receptors not only influence the quality of the radiograph but also have a direct impact on the amount of radiation to which a patien...

In the ever-evolving field of diagnostic imaging, radiation safety is not merely a set of best practices—it is a professional and ethical responsibility. Among the tools available to radiologic technologists, radiographic dose documentation stands out as both a shield and a spotlight. It shields patients from excessive exposure and shines a light on the clinical decision-making that prioritizes patient well-being.
Documenting radiation dose is more than recordkeeping—it’s about accountability, transpar...

Radiation protection in diagnostic radiography is built upon the principle that every exposure carries risk—and therefore, every exposure must be optimized. Among the core strategies used to reduce unnecessary patient dose, filtration stands as one of the most effective and universally applied. While it quietly operates inside the x‑ray tube assembly, its impact on skin dose, organ exposure, beam quality, and compliance with national safety standards is profound.
Filtration does far more than “clean up...

Minimizing radiation exposure is not solely a matter of adjusting machines or applying technical filters—it also demands careful attention to the patient as a dynamic, central part of the imaging process. In this third installment of our series on radiation safety, we turn our focus to patient considerations, exploring how thoughtful approaches to positioning, communication, pediatric care, and imaging morbidly obese patients can significantly reduce unnecessary exposure while maintaining diagnostic qua...

When it comes to diagnostic imaging, minimizing radiation exposure is not just good practice—it is a professional and ethical imperative. One of the most effective strategies in radiation protection is beam restriction, a technique that directly limits the area of the patient exposed to the primary x-ray beam. This second installment in our series on minimizing patient exposure focuses on the purpose and methods of primary beam restriction.
The Purpose of Primary Beam Restriction
At its core, the prim...

In diagnostic radiology, protecting patients from unnecessary radiation exposure is both an ethical imperative and a regulatory requirement. As medical imaging technologies become more advanced and accessible, the responsibility to optimize exposure without compromising image quality grows increasingly important. Central to this task are three primary exposure factors: kilovoltage peak (kVp), milliampere-seconds (mAs), and automatic exposure control (AEC). Each of these parameters plays a distinct role ...

When radiation interacts with the human body, it unleashes a cascade of biological effects. These effects vary based on the energy of the radiation, the type of tissue involved, and the duration and intensity of exposure. In this third installment of our series on the biological effects of radiation, we zero in on radiosensitivity—the measure of how likely cells, tissues, and systems are to be damaged by ionizing radiation. For radiography students and professionals preparing for the ARRT Registry, a de...

Radiation's interaction with living tissue is not uniform — some cells and systems are more vulnerable than others. This property, known as radiosensitivity, is central to understanding diagnostic imaging, radiation therapy, and radiation protection principles. For those preparing for the ARRT Registry, mastering this concept is essential.
In this second part of our blog series on the biological effects of radiation, we will explore the factors that influence radiosensitivity, including dose-response r...

Radiation has long been both a marvel and a menace in the medical world, powering life-saving diagnostic imaging while also carrying risks that must be meticulously managed. At the heart of understanding radiation’s biological effects lies the precision of measurement. That’s where SI (International System of Units) comes in—a globally adopted framework that enables radiologists, physicists, and health professionals to communicate and calculate radiation doses with consistency and clarity.
In this firs...